r
Victron Battery Protect 12/24V-220A
The Victron Energy BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. 12/24V auto ranging: The BatteryProtect automatically detects system voltage Fully programmable with simple ‘countdown’ program: The BatteryProtect can be set to engage / disengage at several different voltages with a simple ‘count down’ program. Over voltage protection: To prevent damage to your sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16 V respectively 32 V. Ignition proof: No relays but MOSFET switches, and therefore no sparks. Delayed alarm output: The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 15 seconds. Starting the engine will therefore not activate the alarm. The alarm output is an open collector output to the negative (minus) rail, max. current 500 mA. The alarm is typically used to activate a buzzer and / or lamp. Delayed load disconnect: Only 1 minute after the alarm has been activated will the load be disconnected. If battery voltage increases to the connect threshold within this minute (after the engine has been started for example) the load will not be disconnected. Features: