Victron Energy SmartSolar MPPT 100/15 Solar Charge ControllerA solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
Bluetooth Smart built-in The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers. VE.Direct For a wired data connection to a Color Control GX, other GX products, PC or other devices Ultra-fast Maximum Power Point Tracking (MPPT) Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Load output Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a pre-set voltage (48V model: interface with a relay). The load output is short circuit proof.
Battery Life: intelligent battery management When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards, the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week. Programmable battery charge algorithm
Internal temperature sensor Compensates absorption and float charge voltage for temperature. Optional external battery voltage and temperature sensing via Bluetooth A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.
Fully discharged battery recovery function Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with integrated disconnect function. Specifications: Battery voltage (auto select)
| 12/24V | Rated charge current
| 15A | Nominal PV power, 12V
| 220W | Nominal PV power, 24V
| 440W | Max. PV short circuit current
| 15A | Automatic load disconnect
| Yes | Max. PV open circuit voltage
| 100V | Peak efficiency
| 98%
| Self-consumption – load on 12V:
| 19 mA 24V: 16 mA | Self-consumption – load off
| 12V: 10 mA 24V: 8 mA | Charge voltage 'absorption'
| 14,4V / 28,8V (adjustable) | Charge voltage 'float'
| 13,8V / 27,6V (adjustable) | Charge algorithm
| multi-stage adaptive | Temperature compensation
| -16 mV / °C resp. -32 mV / °C | Max. continuous load current
| 15A | Low voltage load disconnect
| 11,1V / 22,2V or 11,8V / 23,6V or Battery Life algorithm | Low voltage load reconnect
| 13,1V / 26,2V or 14V / 28V or Battery Life algorithm | Protection
| Output short circuit / Over temperature | Operating temperature
| -30 to +60°C (full rated output up to 40°C) | Humidity
| 95%, non-condensing | Data communication port
| VE.Direct (see the data communication white paper on our website) | Colour
| Blue (RAL 5012) | Power terminals
| 6 mm² / AWG10 | Protection category
| IP43 (electronic components), IP22 (connection area) | Weight
| 0,6 kg | Dimensions (h x w x d)
| 100 x 113 x 50 mm | STANDARDS
| Safety EN/IEC 62109-1, UL 1741, CSA C22.2 |
|